| Date Built: |
1960 |
| Last Renovated: |
1982 |
| Size H/W/L: |
3.25 x 2.8 m |
| Max Wind Speed: |
90 m/s |
| Construction Type: |
Closed, Slotted, Open |
| Reynolds Number: |
1.8 x 10^6 |
| Circuit Type: |
Return |
| Power: |
1400 kW |
| Power Type: |
Single Stage Fan |
| Stagnation Pressure/Temperature: |
Ambient / Ambient |
| Data System: |
HP 1000 F, HP 1000 E, HP 1000 A400 |
| Data Acquisition: |
Static data (64 simplex), Dynamic data (1 simplex, 24 duplex) |
| Balances: |
External, Internal |
| Ground Effects: |
none |
| Test Types: |
Full and Half model, 2-D Dynamics, Model cars, Trains |
| Air Supply System: |
33 bar |
| Air Mass Flow: |
1.8 kg/sec |
| Tunnel Diagrams & Images: |

|