| Date Built: |
1968 |
| Size H/W/L: |
20' x 20' x 42' |
| Max Wind Speed: |
230 kts |
| Construction Type: |
Closed, Slotted, Open, and ¾ Open |
| Reynolds Number: |
0 to 2.3 x 10^6 |
| Circuit Type: |
Single Return |
| Power: |
15,000 hp |
| Power Type: |
9 Bladed Fan |
| Stagnation Pressure/Temperature: |
Ambient / Ambient |
| Data System: |
HP/LMS VXI, PDP 11/84, VAX 11/780 |
| Data Acquisition: |
Channels: 190 Analog to 100kHz, 16 Digital, 16 Pulse Count |
| Pressure System: |
PSI Electronic Pressure Scanner, Scanivalves, Discrete Static/Dynamic Transducers |
| Balances: |
Internal, External |
| Ground Effects: |
Moving Belt, Fixed Ground Plane |
| Test Types: |
Rotary Wing, Fixed Wing, V/STOL, Aerodynamics, Ground Vehicles, Acoustic, Hover |
| Air Supply System: |
1000 psi, 70°F to 250°F |
| Air Mass Flow: |
20 lb/sec |